Siemens Network Hardware D410 ユーザーズマニュアル

ページ / 150
 
Maintenance and service 
 
5.4 SIMOTION CompactFlash Card 
D410 
Commissioning Manual, 08/2008 Edition 
133
 
5.4.4 
Bootloader on the CompactFlash card 
Writing a bootloader 
A bootloader may need to be written in the following situations: 
●  When a new bootloader is required for the used SIMOTION D410 firmware version. 
●  When a new bootloader is required for the used SIMOTION D410 hardware version. 
●  When the bootloader is defective. 
The bootloader version can be fetched using the SIMOTION SCOUT device diagnosis. If this 
is not possible because of the following reason, this can be caused by an incorrect 
bootloader version. In this case, replace the bootloader version with the current version. 
●  The SIMOTION D410 does not startup, the RDY LED flashes red at 0.5 Hz and the 
RUN/STOP LED lights red or all LEDs remain off. 
Use the "Options > Write boot sector..." function to write the bootloader version in the 
SIMOTION SCOUT to the CF card. 
Detailed information for the CF card, bootloader version, SIMOTION D410 hardware and 
SIMOTION firmware version compatibility relationships is contained in the software 
compatibility list. This list is available both in the supplied documentation of the SIMOTION 
SCOUT CD at \1_Important\German\Kompatibilität\ . . . and also in the Internet at