Siemens AT Command Set Cellular Engines Wireless Modules MC35 ユーザーズマニュアル

ページ / 238
AT Command Set
MC35_ATC_01_V04.00
Page 143 of 238
02.04.2002
<usedx> Number of messages currently in <memx>
<totalx> 
Number of messages storable in
 <memx>
Reference
GSM 07.05
Note
•  The Mobile Equipment storage "ME" offers space for 25 short messages.
•  The storage "MT" is the sum of the storages "ME" and "SM". The indices (<in-
dex>) from 1 to 25 are associated to the "ME" storage. Indices equal to 26 and
higher are allocated to the "SM" storage.
•  <mem1> and <mem2> are set to “MT” by default. Alternatively, the two pa-
rameters “SM” or “ME” can be selected during the current session, giving ac-
cess either to the SIM card storage or to the device storage. Once the module
is powered down or reset the default setting “MT” will be restored.
•  <mem3> memory is set to “MT” and does not offer the choice between “SM”
and “ME”. The user should be aware that “MT” involves “ME” and “SM”, with
“ME” being filled up first. If the "ME" storage is full, MC35 will proceed with the
"SM" storage.
Incoming Class 1 short messages (ME specific) will be preferably stored to
“ME” and may be transferred to the “SM” storage if “ME” is used up.
Incoming Class 2 messages (SIM specific) will be stored to the SIM card only,
no matter whether or not there is free “ME” space.
As a result, the ^SMGO: 2 indication (see AT^SMGO in Chapter 8.15 may be
presented without prior indication of ^SMGO: 1. For more information regarding
SIM and ME specific message classes refer to <dcs> and the following specifi-
cations: GSM 03.38 and 3GPP TS 23.038.