Siemens AT Command Set Cellular Engines Wireless Modules MC35 ユーザーズマニュアル

ページ / 238
AT Command Set
MC35_ATC_01_V04.00
Page 145 of 238
02.04.2002
5.13  AT+CSCB  Select cell broadcast messages
Test command
AT+CSCB=?
Response
+CSCB: (list of supported <mode>s)
Parameter
See write command
Read command
AT+CSCB?
Response
+CSCB: <mode>,<mids>,<dcss>
Parameter
See write command
Write command
AT+CSCB=[<mode>
[,<mids>[,<dcss>]]]
Parameter
<mode>
0
Accepts messages that are defined in <mids> and <dcss>
1
Does not accept messages that are defined in <mids>
and <dcss>
<mids>
String type; combinations of CBM message IDs (e.g.
"0,1,5,320-478,922"). The number of ranges in <mids> pa-
rameter string is limited to 6
<dcss>
String type; combinations of CBM data coding schemes (e.g.
"0-3,5")
Note:
If <mode>=1 is selected the parameter <mids> has to be given as only one
area (e.g. “0-99“)
Reference
GSM 07.05
Note