Siemens AT Command Set Cellular Engines Wireless Modules MC35 ユーザーズマニュアル

ページ / 238
AT Command Set
MC35_ATC_01_V04.00
Page 147 of 238
02.04.2002
5.15  AT+CSMP  Set SMS text mode parameters
Test command
AT+CSMP=?
Response
OK
Read command
AT+CSMP?
Response
+CSMP:<fo>,<vp/scts>,<pid>,<dcs> OK
Parameter
See set command
Set command
AT+CSMP=
<fo>[,<vp/scts>[
,<pid>
[,<dcs>]]]
Response
TA selects values for additional parameters needed when SM is sent to the net-
work or placed in a storage when text format message mode is selected. It is pos-
sible to set the validity period starting from when the SM is received by the SMSC
(<vp> is in range 0... 255) or define the absolute time of the validity period termi-
nation (<vp> is a string). The format of <vp> is given by <fo>. If TA supports the
enhanced validity period format, see GSM 03.40), it shall be given as a hexadezi-
mal coded string (refer e.g. <pdu>) with quotes.
Note:
When storing a SMS_DELIVER from the TE to the preferred memory storage in
text mode (refer write command to Message Memory +CMGW), <vp> field can be
used for <scts>
Parameter
<fo>
depending on the command or result code: first octet of GSM 03.40
SMS-DELIVER, SMS-SUBMIT (default 17), or SMS-COMMAND (default
2) in integer format
<scts>
GSM 03.40 TP-Service-Centre-Time-Stamp in time-string format (refer
<dt>)
<vp>
depending on SMS-SUBMIT <fo> setting: GSM 03.40 TP-Validity-Period
either in integer format (default 167) ), in time-string format (refer <dt>),
or if is supported, in enhanced format (hexadecimal coded string with
quotes)
<pid>
Protocol-Identifier in integer format (default 0), refer GSM 03.40
<dcs>
SMS Data Coding Scheme (default 0), or Cell Broadcast Data Coding
Scheme in integer format depending on the command or result code:
GSM 03.38
Reference
GSM 07.05
Note
The command writes the parameters to the non-volatile memory.