8.10  AT^SDLD  Delete the “last number redial“ memory
Test command
AT^SDLD=?
Response
OK
Execute command
AT^SDLD
The execute command deletes all numbers stored in the LD memory.
Response
OK/ERROR/+CME ERROR
Reference
Siemens
Note
8.11  AT^SHOM  Display Homezone
Test command
AT^SHOM=?
Response
OK
Parameter
See execute command
Execute command
AT^SHOM
Response
TA returns homezone state
^SHOM: <homezonestate> OK
Parameters
<homezonestate>
0
ME is out of Homezone
1
ME is within the Homezone
Reference
Siemens
Note
8.12  AT^SLCD  Display Last Call Duration
Test command
AT^SLCD=?
Response
OK
Parameter
See execute command
Execute command
AT^SLCD
Response
TA returns last call duration or current call duration
^SLCD: <time> OK
Parameter
<time>
string type value; format is "hh:mm:ss", where characters indicate hours,
minutes, seconds; e.g. 22:10:00 “22:10:00",
max values are 9999:59:59
Reference
Siemens