Siemens AT Command Set Cellular Engines Wireless Modules MC35 ユーザーズマニュアル

ページ / 238
AT Command Set
MC35_ATC_01_V04.00
Page 191 of 238
02.04.2002
8.15  AT^SMGO  Set or query SMS overflow presentation mode or query SMS
overflow
Test command
AT^SMGO=?
Response
^SGMO: (list of supported <n>s) OK
Parameter
See write command
Read command
AT^SMGO?
Response
TA returns overflow presentation mode and SMS overflow status
^SGMO: <n>,<mode> OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameter
See write command
Write command
AT^SMGO=<n>
Response
TA sets overflow presentation mode
OK
Parameter
<n> 
SMS overflow presentation mode
0 disable (default)
1 enable
<mode>  SMS overflow status
0
space available
1
SMS buffer full (buffer for received short messages is <mem3>. See
AT+CPMS in Chapter 5.11)
2
Buffer full and new message waiting in SC for delivery to ME
Unsolicited result code
When the status SIM overflow changes, an unsolicited result code is sent to TE
^SMGO: <mode>
Parameter
See write command
Reference
Siemens
Note
•  Indication during data transfer via break (100ms).
•  Incoming Class 1 short messages (ME specific) will be preferably stored to
“ME” and may be transferred to the “SM” storage if “ME” is used up. Incoming
Class 2 messages (SIM specific) will be placed to the “SM” storage only.
If messages with different classes are received, the ^SMGO: 2 indication may
be presented, without prior indication of ^SMGO: 1. The indication ^SMGO: 1
means that both buffers ("ME" and "SM") are full. See also Chapter 5.11.
•  For more information regarding SIM and ME specific message classes refer to
<dcs> and the following specifications: GSM 03.38 and 3GPP TS 23.038.