2.36  AT&S  Set circuit Data Set Ready (DSR) function mode
Write command
AT&S<value>
Response
This parameter determines how the TA sets circuit 107 (DSR) depending on the
communication state of the TA interfacing TE.
OK
Parameter
<value>
0
DSR always on.
1
TA in command mode: DSR is OFF.
TA in data mode: DSR is ON.
Reference
V.25ter
Note
Line state refers to RS-232 levels.