Siemens AT Command Set Cellular Engines Wireless Modules MC35 ユーザーズマニュアル

ページ / 238
AT Command Set
MC35_ATC_01_V04.00
Page 31 of 238
02.04.2002
2.32  ATZ  Set all current parameters to user defined profile
Execute command
ATZ[<value>]
Response
TA sets all current parameters to the user profile stored with AT&W (see Chapter
2.38 on page 35). If a connection is in progress, it will be terminated. All defined
GPRS contexts which are not activated or not online will be undefined (see
+CGDCONT,+CGQREQ,+CGQMIN commands). The user defined profile is
stored to the non-volatile memory.
Note: If invalid, the user profile will be reset to the factory default profile. Any ad-
ditional commands on the same command line will be ignored. A delay of 300 ms
is required before next command is sent, otherwise “OK” response may be cor-
rupted.
OK
Parameter
<value> 0 Reset to user profile
Reference
V.25ter
Note
The GSM engines referred to in this manual can be assigned two profiles: the
factory profile (restored with AT&F) and the user profile (stored with AT&W). See
Chapter 2.35 for details on AT&F.
2.33  AT&C  Set circuit Data Carrier Detect (DCD) function mode
Write command
AT&C[<value>]
Response
This parameter determines how the state of circuit 109(DCD) relates to the de-
tection of received line signal from the distant end.
OK
Parameter
<value>
0
DCD line is always ON.
1
DCD line is ON in the presence of data carrier only.
Reference
V.25ter
Note
Line state refers to RS-232 levels.