Siemens AT Command Set Cellular Engines Wireless Modules MC35 ユーザーズマニュアル

ページ / 238
AT Command Set
MC35_ATC_01_V04.00
Page 53 of 238
02.04.2002
3.25  AT+FTM  Transmit Data
Test command
AT+FTM=?
Response
(List of supported modulation modes)
 OK
Parameter
See write command
Write command
AT+FTM=<mod>
This command causes the TA to transmit data using the modulation mode de-
fined below. An ERROR response code results if this command is issued while
the modem is on-hook.
Response
CONNECT
If error is related to ME functionality:
ERROR
Parameter
<mod>
modulation mode
96
V.29
9600 bps
72
V.29
7200 bps
48
V.27ter
4800 bps
24
V.27ter
2400 bps
Reference
TIA/EIA-578
Note
Used for Fax class 1 only
3.26  AT+FTS  Stop Transmission and Wait
Write command
AT+FTS=<time>
This command causes the TA to terminate a transmission and wait for <time> 10
millisecond intervals before responding with the OK result code to the DTE.
Response
An ERROR response code results if this command is issued while the modem is
on-hook.
Parameter
<time>
0 – 85
no. of 10 millisecond intervals
Reference
TIA/EIA-578
Note
Used for Fax class 1 only