Saab Automobile Accessories G3 ユーザーズマニュアル

ページ / 110
30
Service Manual
Third edition, June 1997
3.13
Level Unit – Trim/List Data
The Trim/List Data-window shows the measured trim and
list angles. They are displayed as 1/100 of degrees.
The source of the trim and list values are shown in the Ship
measures-window in the Configure-part of the software.
Open the Ship measures-window by hitting the Window-key
and selecting Configure. Then hit the Picture-button and
select Calculation and Ship data.
The dynamic data box is divided into three parts for LCI,
LCM 1 and LCM 2. The LCM 1 and 2 read trim and list val-
ues produced by the Trim/List Unit mounted in the Level
Unit cabinet. The LCI receives its trim and list values from
draft sensors, separate inclinometer, from external communi-
cation or if it is manually entered.
The status boxes show.
Trim or list sens fail
. The sensor in question is faulty.
Trim or list manual
. This box is checked if manual
values for trim and list have been entered.
In the database box the following is shown and can be
changed:
LT sensor type
. Enter 0 if no trim and list sensor is
connected. Enter a 1 if the standard Trim/List Unit is
used.
Trim or list offset
. If you find that the trim/list values
displayed by TankRadar are not correct, their offset can
be programmed in the database box. The offset is
shown in 1/100 degrees angle. For example, enter 5 to
set a 0.05
°
 offset.