Saab Automobile Accessories G3 ユーザーズマニュアル

ページ / 110
42
Service Manual
Third edition, June 1997
Database registers can be changed. Type in a new value and
hit the Save-button.
Note:
 You must be sure that you are changing the correct register,
as many of the registers lack a descriptor.
A list of a few of the database registers of the LCI is included
below:
Reg no. Name
Description
00
Port_1_protocol
To Work Station
01
Port_1_baudrate
To Work Station
02
Port_1_databits
To Work Station
03
Port_1_stop bits
To Work Station
04
Port_1_parity
To Work Station
05
Port_2_protocol
To Service PC
06
Port_2_baudrate
To Service PC
07
Port_2_databits
To Service PC
08
Port_2_stop bits
To Service PC
09
Port_2_parity
To Service PC
10
LU_setup
0=fast update, 1= redundance
11
Relay_4_control
0=off, 1=on
12
Relay_5_control
0=off, 1=on
20
LCB_TrimList_corr 0=off, 1=on
21
LCB_ullage_unit
0=m, 1=feet
22
LCB_temp_unit
0=
°
C, 1=
°
F
23
LCB_press_unit
0=mbar, 1=PSI
50
LI_1_handler
0=none, 1=LCM1, 2=LCM2
51
LI_2_handler
0=none, 1=LCM1, 2=LCM2
52
LI_3_handler
0=none, 1=LCM1, 2=LCM2
53
LI_4_handler
0=none, 1=LCM1, 2=LCM2
100
Number of tanks
101
Display shutdown timeout
in seconds