Renesas R61509V ユーザーズマニュアル

ページ / 181
R61509V 
        Target 
Spec 
 
Rev. 0.11 April 25, 2008, page 73 of 181  
 
Power Control3 (R102h) 
Note: True values of PSON and PON are not read when instruction read is executed.  
 
PON, PSON: Turn power supply ON. PON and PSON must be written to power supply ON and start the 
internal power supply operation. Follow power supply sequencer to set PON and PSON bits.  
VCMR: Selects either external resistance (VCOMR pin) or internal electronic volume (VCM[4:0]) to set 
the electrical potential of VCOMH.  The internal electronic volume is set by VCM bits 
Table 44 
VCMR0[0] 
VCOMH Electrical Potential setting 
0 VCOMR 
(externally 
supplied) 
 
1 Internal 
electronic 
volume 
 
VRH[3:0]: Sets the factor to generate VREG1OUT.  
Table 45  
Note: Write VC and VRH bits so that VREG1OUT ≤ DDVDH-
0.5V.  
 
 
 
 
 
R/W  RS  IB15 IB14 IB13 IB12 IB11 IB10 IB9
IB8
IB7
IB6
IB5
IB4
IB3  IB2  IB1  IB0 
VRH 
[4] 
VRH 
[3]
VRH 
[2] 
VRH 
[1] 
VRH
[0]
0 0 
VCM
1 0 
PSON PON
0 0 0  0 
R/W 1 
R/W R/W R/W R/W R/W
 
  R/W R/W
 
W
W
 
 
 
 
Default 
 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0  0 
VRH[4:0] VREG1OUT 
5’h00 Halt 
(Hiz) 
5’h01-5’h0F 
Setting inhibited  
5’h10 
VCIR x 1.600 
5’h11 
VCIR x 1.625 
5’h12 
VCIR x 1.650 
5’h13 
VCIR x 1.675 
5’h14 
VCIR x 1.700 
5’h15 
VCIR x 1.725 
5’h16 
VCIR x 1.750 
5’h17 
VCIR x 1.775 
5’h18 
VCIR x 1.800 
5’h19 
VCIR x 1.825 
5’h1A 
VCIR x 1.850 
5’h1B 
VCIR x 1.875 
5’h1C 
VCIR x 1.900 
5’h1D 
VCIR x 1.925 
5’h1E 
VCIR x 1.950 
5’h1F 
VCIR x 1.975