Powermaster Safety Gate UL 991 ユーザーズマニュアル

ページ / 22
 
33 
3.  Leaving enough wire for the LEAD IN, insert the 
specified number of turns of wire in the cut grooves.  
(See chart). 
 
CAUTION: Be careful not to damage the wire 
insulation during installation. 
4. After completing the required number of loop turns, 
twist the ends together at the rate of turns per foot to 
form the LEAD-IN. 
 
5. Seal  the  LEAD-IN wire in the conduit to prevent 
moisture seepage into the conduit. 
 
6. Fill over the loop wires in the groove with a 
recommended loop sealant.  Contact your distributor 
for available sealants. 
 
7. Mount the loop detector in the operator and connect 
the wire loop. 
   
8. Connect loop detector to the control board as shown 
on the following page. 
 
 
 
 
34 
V
OR
R
P
Not Used
BL
BK
WH
Y
GR
BR
GY
TO 
DRIVEWAY
LOOP
SHADOW LOOP CONNECTION
NOTE:  TWIST LEADS APPOX. 
             6 TURNS PER FOOT.
7
8
9
A
B
Red Wire From 
Aux. Open Limit
10
V
OR
R
P
Not Used
BL
BK WH
Y
GR
BR
GY
TO DRIVEWAY
LOOP
NOTE:  TWIST LEADS APPOX. 
             6 TURNS PER FOOT.
EXIT LOOP CONNECTION
2
3
4
5
A
B
V
OR
R
P
Not Used
BL
BK
WH
Y
GR
BR
GY
TO 
DRIVEWAY
LOOP
REVERSING LOOP CONNECTION
NOTE:  TWIST LEADS APPOX. 
             6 TURNS PER FOOT.
7
8
9
10
A
B