Perlick DS ユーザーズマニュアル
cleaning the cabinet
Direct Draw Dispensers Self-Contained
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice
6
Form No.Z2278
Rev. 11.29.10
draft beer information
Direct Draw Dispensers Self-Contained
temperature
One of the most common causees of dispensing problems is improper temperature. Draft beer should
be stored at a temperature between 32°F and 38°F. At warmer temperatures, beer will foam.
At temperatures lower than 30°F, beer will freeze. When beer freezes, the alcohol in the beer may
separate and cause the beer to be cloudy with an “off” taste.
28°
30°
32°
34°
36°
38°
40°
44°
42°
Freezes
Ideal
Foams
HOW TEMPERATURE DRAFT AFFECTS BEER
adjusting the temperature
The temperature control is inside the cabinet on
the right-hand side of the evaporator fan panel
assembly. You will need a screw driver to turn the
adjusting screw. Make small adjustments until the
desired temperature is achieved
■
Colder Temperatures:
Turn the adjusting screw clockwise (to the
right)
■
Warmer Temperatures:
Turn the adjusting screw counterclockwise
(to the left)
The condenser fan motor turns off and on with
the condensing unit. The evaporator fan motor
runs continuously. The fan motors are lifetime
lubricated and will require no oiling.
NOTE: Cabinet temperatures lower than
34° will not allow for proper defrosting of the
evaporator coil. If defrosting is necessary, turn
the control knob to the
OFF position until coil is
defrosted.
refrigerator and temperature
control
The Direct Draw Dispenser is equipped with
a heavy-duty refrigeration system designed to
automatically maintain a storage temperature of
36°-41°F. The control is factory set at 38°F.
C
O
O
LE
R
OFF
1
2
3
4
5
6
COLD