WIPER
The following IPSXM unit models feature a window wiper to clear moisture from the window of the 
enclosure: 
IPSXM31C22-2
IPSXM31C22-7
IPSXM31C22-2X
IPSXM31C22-7X
IPSXM31CBW23-2
IPSXM31CBW23-2X
IPSXM31CBW23-7
IPSXM31CBW23-7X
NOTE:  The Wiper menu is available only on the above models. To check the unit model, refer to the 
System Information section of this manual. 
WIPER CONTROL
This feature programs the on/off control for the wiper. There are two available settings for wiper 
control, AUX 1 and Preset 86. If the wiper control is programmed for AUX 1, the wiper will operate 
when AUX 1 is accessed. If the wiper control is set to Preset 86, selecting preset 86 on your 
controller will turn the wiper on/off. 
WIPER MODE
Wiper mode determines how the wiper will act after the wiper control is turned on/off. There are 
two modes of operation for wiper mode, momentary and continuous. 
WIPER DWELL
The wiper can be programmed to wipe the enclosure window every 1 to 30 seconds. This setting 
only works when the wiper is programmed for continuous mode. The dwell time can be programmed 
from 1 to 30 seconds.
WIPER TIME
Wiper time programs how long the wiper will be on before it automatically shuts off. This setting 
only works when the wiper is programmed for continuous mode. Wiper time can be programmed 
from 1 to 1,440 minutes (1 minute to 24 hours).
NOTE:  CM9700 Matrix Systems Only – For the wiper to operate in continuous mode, the   camera’s 
AUX 1 relay function must be set to latching in the CM9700-MGR. If the AUX 1 camera file is not 
latching, the wiper will operate only in momentary mode, even if the system wiper is programmed 
for continuous operation. Refer to the CM9700-MGR Software Guide for instructions.
<CAMERA>
<MOTION>
<POWER UP>
<LINE SYNC>
<PRESETS>
<PATTERNS>
<ZONES>
<WINDOW BLANKING>
<ALARMS>
<WIPER>
<AUX>
<CLEAR>
<PASSWORD>
BACK
EXIT
UNIT SETTINGS
WIPER CONTROL  
AUX 1
WIPER MODE  
CONTINUOUS
WIPER DWELL (SECS)  
2
WIPER TIME (MINS)  
60
<SET WASHER SEQUENCE>
BACK
EXIT
WIPER*
 * Available only with the wiper models.
EXIT
LANGUAGE  
ENGLISH
UNIT INVERSION  
OFF
<SYSTEM INFORMATION>
<DISPLAY SETUP>
<UNIT SETTINGS>
<POSITION CALIBRATION>
RESET CAMERA
CYCLE CAMERA POWER
REBOOT SYSTEM
PELCO EXSITE IPSXM
MOMENTARY 
(default)
Programs the wiper to move across the enclosure window once and then back 
to its starting position. 
CONTINUOUS
Programs the wiper to operate continually after the wiper is turned on. The 
wiper will continue to operate until the wiper control (AUX 1 or preset 86) is 
pressed again or until the programmed wiper time is completed.