Toshiba VF-AS1 ユーザーズマニュアル

ページ / 326
!
  E6581301 
J-11 
10 
 How to install
Add-on type devices and insertion type devices are installed in different ways. Install them correctly, as shown in the 
figures below. 
Add-on type 
Plug-in type
Up to two Add-on type devices and one Plug-in type 
device can be installed at the same time. Note, 
however, that two identical optional devices and two 
identical optional communication devices cannot be 
connected and used.
Depending on the capacity, the installation of an Add-on type device may increase the depth of the inverter.   
200V    0.4~45kW 
400V    0.75~37kW 
400V    45~75kW 
200V    55, 75kW 
400V    90~500kW 
Note: The inverters of these 
capacities come equipped with 
an Add-on type option case as 
standard. When installing an 
optional Add-on type device, 
remove the case. 
Standard type
  one Add-on 
Standard type
Standard type
  two Add-on