Tascam RS-232C HD-R1 ユーザーズマニュアル

ページ / 16
 
 
 
 
TASCAM HD-R1 RS-232C Protocol Specifications 
                                                                                                 
 
 
TEAC Corporation
 
 
Controlled device (this unit) 
Control device   
 
 
3. Command format   
 
3.1 Command format overview   
The serial protocol was designed to be able to function using common terminal programs. Therefore, all markers are 
printable 8-bit ASCII characters, and the end of line marker is flexible. Unless otherwise indicated, character strings 
are not case sensitive. Every message has the same structure as indicated below, but some messages do not contain all 
the fields defined below.   
 
Parameter  ID:  A  string of 1–24 characters specifies the parameter handled,  including queries. Spaces before and 
after parameter character strings are ignored. Unless otherwise indicated, character strings are not case sensitive, and 
do not contain equal signs, question marks or exclamation points.   
 
Command: One character defines what the command does. This is the same for queries.   
Commands include “=” (set value) and “?” (query).   
 
Value: Strings are of 1 to 24 characters, including query values. Spaces before and after character strings are ignored. 
Unless otherwise indicated, character strings do not distinguish between upper and lower case characters.   
 
End Marker: One or two  character  strings. Both  a  carriage return  followed by a line-feed  (CR LF)  and a line-feed 
(LF) are valid. The HD-R1 always accepts either type of end marker, and it can also send them.   
 
Below  is  an  example  of  a  typical  message. There  are  no  blank  spaces  inserted  after  the  Parameter  ID  and  Value 
character strings, and one end marker character string is used.