TASCAM HD-R1 RS-232C Protocol Specifications 
                                                                                                 
 
 
TEAC Corporation
 
Output commands 
Parameter value response   
When the command field of a message being set contains “=” (equal sign), the HD-R1is reporting the current value of 
the parameter. Usually, character strings for parameter IDs and their values match the text shown on the LCD user 
interface screen. For example: 
  Input Source? 
  Input Source=S/PDIF 
 
Error responses 
When the command field of a message being sent to it contains “?” (question mark), if the HD-R1 cannot interpret 
the received message it reports an error. For example, the HD-R1 will respond as follows if it
 
receives a parameter 
query for an invalid parameter called “Blah.” 
  Blah? 
  Blah??? 
 
If the HD-R1 receives an invalid parameter set command, it will respond as follows.   
  Blah=Foo 
  Blah???Foo 
 
Set value refusal responses 
If  the  HD-R1  receives  a  parameter  set  command  for  a  valid  parameter,  but  the  value  is  invalid,  the  HD-R1  will 
respond with “!” (exclamation point) added to the command field.   
  Input Source=Blah 
  Input Source!Blah 
 
If  the  HD-R1  receives  a  parameter  set  command  for  a  valid  parameter,  but  the  value  is  missing,  the  HD-R1  will 
respond as follows.   
  Input Source= 
  Input Source!Missing Value 
 
Some parameters  can be  applied only when the transport is stopped.  If you  try to  change one of  these parameters 
when  the  transport  is  not  stopped,  the  HD-R1  responds  with  “*”  (asterisk).  For  example,  if  you  try  to  change  the 
sampling frequency while recording, the HD-R1 will respond as follows.   
  WAV Sample Rate=44.1 kHz   
  WAV Sample Rate*44.1 kHz 
 
Special incoming commands 
End markers   
By sending a  line  feed  (LF) or  carriage return and line feed (CR  LF), the HD-R1  can be informed of  the  end of a 
message. The HD-R1 can accept this query or command at any time. After turning the power on, the end marker is 
set to CR LF by default. The following are end marker setting commands. 
  End Marker=LF 
  End Marker=CR LF