OPERATING THE STOVE USING A THERMOSTAT 
 
A thermostat may help you maintain a constant house 
temperature automatically. A millivolt thermostat or 24 Volt 
thermostat is required. A fixed wall mount or hand held model can 
be used. The control panel can be set up two ways to operate 
your stove in thermostatic mode. 
THERMOSTAT INSTALLATION 
 
• 
Unplug the stove from the power outlet. 
• 
Connect two thermostat wires to the terminal block located 
on the lower right side of the back of the stove. To do so, 
loosen the two screws and insert the wires in the terminals. 
Tighten the two screws. (See figure 16) 
• 
If you are using a wireless wall thermostat or a hand held 
thermostatic remote control, you can locate the receiver 
behind the stove’s back panel, on the right end side, just 
below the terminal block.  Most receivers are already 
equipped with quick-connect terminals.  Simply unplug the 
PC board wires connected to the back of the terminal block 
and connect them directly with the receiver’s terminals.   
Location of the thermostat is very important to obtain the 
best comfort and efficiency from you Hybrid-45 MF.  The 
thermostat should be mounted 50 inch from the floor on a 
wall located 15 to 20  feet from the stove.  You should avoid 
an installation directly in front of the stove to avoid 
cycling.(See figure 17) 
MODES 
 
THERMOSTATIC MODE 
• 
To use this mode, the “MODE” button must be pushed to 
“Thermostat” upon starting the stove. The heat setting is then 
selected using the “Heat Level” selector “+ or –“. When set in 
thermostatic mode, the stove will automatically run a the heat 
level selected until the set room temperature is reached. 
When that occurs, the stove will switch to heat setting #1 
(lowest) until the thermostat calls for heat again.  The 
convection blower will also slow to its lowest speed. When 
the thermostat calls for heat again, the stove will increase its 
feed rate to match the heat  setting selected.  
 
• 
N.B.:  If the room temperature remains stable and the 
thermostat does not call for heat  during at least 45 minutes, 
the stove will shut down.  When the thermostat calls for heat 
again, the stove will start an ignition cycle.  Once the ignition 
cycle is completed, the stove  will increase its feed rate to 
match the heat  setting selected.  
 
 
NOTE: When in  thermostatic mode: 
 
• 
You should not operate the manual control or play with the 
temperature setting. 
 
• 
YOUR THERMOSTAT SHOULD BE INSTALLED BY AN 
AUTHORIZED DEALER OR SERVICE PERSON. 
 
The size of wires will vary with the distance: 
 
DISTANCE         DIAMETRE 
    20 pi                     18GA 
    30 pi                     16GA 
    40 pi                     14GA 
    50 pi                     12GA 
 
THERMOSTAT WIRES
TERMINAL
 
 
 
 
 
 
D = MINIMUM DISTANCE 15 FEET
SHOULD BE AVOIDED
 
 
 
 
 
 
 
 
THERMOSTAT INSTALLATION 
14 
FIGURE 16 
Rear view 
FIGURE 17 
Thermostat location