FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS 
INDICATED CAN RESULT IN POOR PERFORMANCE AND 
SAFETY HAZARDS. NEVER CLEAN WHEN HOT. 
 
NOTE:  Inspect burn pot periodically to see that holes have not 
become plugged. If so, clean thoroughly. 
 
ASH REMOVAL 
 
Ashes should be placed in a metal container with a tight-fitting lid. 
The closed container or ashes should be placed on a 
noncombustible surface or on the ground, well away from all 
combustible materials pending final disposal. If ashes are 
disposed of by soil burial or otherwise locally dispersed, they 
should be retained in the closed container until all cinders have 
thoroughly cooled. 
 
ASH DISPOSAL  
 
The Osburn Hybrid-45 MF has an ash bin located below the 
firebox. To remove ashes: 
 
a. 
Make sure fire is out and the firebox is cool.
 
 
b. 
Open the door and remove the baffle from the firebox. Close 
the door.
 
 
c.  With the door closed, clean heat exchanger tubes by 
activating the cleaning rod back and forth from front to back. 
(see Cleaning section and Figure 18 & 19) . 
 
d.  Open the door and remove the burn pot by grasping it and 
pulling straight out. Scrape the burn pot with a scraper if 
necessary. Make sure that the burn pot holes are not 
plugged. Empty ashes from the burn pot into the pedestal 
ash bin through the opening at the bottom of the firebox. Put 
the burn pot back in place. Make sure it is level and pushed 
all the way in. 
 
e.  Scrape the ashes in the firebox into the pedestal ash bin 
through the opening or the bottom of the firebox or vacuum 
to remove ashes. 
 
WARNING: Make sure ashes are cool to the touch   
before using a vacuum. 
See “VACUUM USE”. 
 
f. 
Periodically remove and empty the ash bin (see Figure 20) 
by opening the front lid of the pedestal below the ash lip. 
Dispose of ashes properly. 
        (See “ASH REMOVAL” above) 
 
g.  Put the ash bin back into place, making sure that you 
tighten the knob and maintain a good seal.  Inspect gasket 
at the same time to make sure it is in good condition. 
 
CONVECTION
BLOWER
AIR SUPPLY
KNOB
HIGH TEMPERATURE
SWITCH F-160
HIGH TEMPERATURE
SWITCH L-250
 
 
   
 
 
 
 
A
 
 
 
 
 
 
 
 
 
FIGURE 21
Side view
MAINTENANCE
16 
FIGURE 18 
Baffle removal 
FIGURE 19 
Cleaning rod 
FIGURE 20 
Ash drawer