Pulse Outputs
Section 7-6
7-6-3
Specifications
Item
Specification
Acceleration/ decelera-
tion
None
Yes
Trapezoid
None
None (acceleration or 
deceleration)
Yes with separate 
acceleration and 
deceleration rates
Instructions for inde-
pendent-mode posi-
tioning
PULS(886) + 
SPED(885)
PULS(886) (Elec-
tronic Cam Control)
PULS(886) + 
ACC(888)
PLS2(887)
Instructions for contin-
uous-mode speed con-
trol
SPED(885)
---
ACC(888)
---
Output frequencies
Constant specified for 
SPED(885): 0 Hz to 
1 MHz
Word specified for 
SPED(885): 0 Hz to 
1 MHz
0 Hz to 1 MHz
0 Hz to 1 MHz
Although the above ranges can be set for the instructions, the output frequency range is ulti-
mately controlled by the clock frequency. The output frequencies are obtained by dividing the 
clock pulse with an integer dividing ratio, meaning the actual output frequency can be different 
from the set frequency. (Refer to Precautions when Using Pulse Outputs on page 175 for details.)
The settings in the System Setup (Clock) are as follows:
20 MHz
Pulse output frequency range: 400 Hz to 1 MHz
10 MHz
Pulse output frequency range: 200 Hz to 200 kHz
5 MHz
Pulse output frequency range: 100 Hz to 100 kHz
2.5 MHz
Pulse output frequency range: 40 Hz to 50 kHz
1.25 MHz
Pulse output frequency range: 20 Hz to 20 kHz
Frequency accelera-
tion/deceleration rate
---
1 Hz to 9,999 Hz every 2 ms or 1 ms
Duty ratio
50% (fixed)
Pulse output operation 
modes
One of the following can be set for each port in the System Setup.
1) Relative pulse output: 
No. of output pulses = pulse output value
2) Absolute linear pulse output: 
No. of output pulses = |PV of pulse output – target pulse amount|
3) Absolute circular pulse output:
As above. If the circular maximum count is exceeded, the count value returns to 0000 0000 
hex. (Circular maximum count is set in System Setup.)
4) Electronic cam control (linear) (output with absolute position specification:)
The direction is automatically determined from the relation between the PV and target position 
(PV < Target = CW, PV > Target = CCW. No. of output pulses = |PV of pulse output – target 
pulse amount|
5) One-shot pulse output:
Pulse turned ON for specified time between 0.01 and 9,999 ms via STIM(980) instruction
6) Pulse counter timer:
High-precision timer created using the one-shot pulse output function. Pulses are not output 
externally.
7) Electronic cam (circular) (output with absolute position specification):
The direction is automatically determined from the relation between the PV and target position 
(PV < Target = CW, PV > Target = CCW). No. of output pulses = |PV of pulse output – target 
pulse amount)|