ACTIVATION
WARNING:  If the unit is activated at elevations
higher than 14,000 feet (4,270 meters), it will per-
form a diagnostic check and immediately shutdown.
To Activate the Veo 100Nx, press and release the Button.
  Upon manual activation, the unit will enter Diagnostic
Mode (Fig. 13), displaying all segments of the LCD as 8's,
followed by dashes (- -), then a countdown from 9 to 0.
Diagnostic Mode checks the display and Battery voltage to
ensure that everything is within tolerance and functioning
properly.
  When the button is held depressed and the Diagnostic
countdown reaches 00, a Serial Number screen appears
displaying the unit’s Serial Number and firmware code
Revision Number as long as the button is held depressed
(Fig. 14).  Upon releasing the button, the unit shuts Off.
  After manual activation, it will also check the ambient
barometric pressure, and calibrate its present depth as
zero.  At elevations of 2,000 feet (610 meters) or higher, it
will recalibrate itself to measure depth at that higher Alti-
tude.