3.  Place unit on pad making sure minimumum  clearance specifications are met. For minimum 
clearance to combustibles (See
 
Page 22). 
   
 
4.   Lightly mark with a pencil location of pedestal on protective pad. 
 
5.  Next, remove four (4) screws holding heater to stand. Position heater out of way of 
installation area. 
 
6.  Check that pedestal stand is still aligned with marks on protective pad, now mark outside air 
opening in bottom of pedestal stand on to pad. 
 
7.   Mark center line of outside air opening.   Set stand aside for now. 
 
8.  Cut a 4 1/4" diameter hole in pad and continue through floor. 
      CAUTION!! The structural integrity of home floor must be maintained. 
      (Move opening and/or reposition heater location if necessary).   
 
9.  Now, reposition pedestal stand and set on pad being sure to line stand up with reference 
marks. 
 
10. Using an electric drill and 3/8" masonry bit, drill four  (4) holes in protective pad using  
holes in bottom of pedestal stand as a guide.  Be careful to drill  only through pad and not 
into floor.  Change the bit to a 1/4" metal bit and drill through floor. 
 
11. Using four (4) 3/8" x 1-1/2" lag bolts  provided,  secure pedestal  stand  and pad to floor of 
home. 
CAUTION 
 
IF  A THICK FLOOR PROTECTOR IS USED, YOU MAY HAVE TO   
USE  LONGER LAG BOLTS. 
 
 
12. Obtain outside air duct from box in pedestal  kit marked FA P21B.  
 
13. Slip duct down through 4-1/4"  hole until face of outside air duct with screen  wire, contacts  
      bottom of pedestal.  
 
14. Secure outside air duct to inside bottom of pedestal using four  (4) #10x1 screws provided.   
      (See Figure 13). 
 
15. Set heater back onto stand and resecure using screws. 
 
16. NOTE: If home is underpinned, you must duct through underpin as shown. (See Figure 13A). 
UNDER SIDE OF MOBILE HOME FLOOR 
Figure 13 
OUTSIDE AIR DUCT  
FLOOR PROTECTOR PAD  
 
PEDESTAL 
OUTSIDE AIR DUCT THROUGH FLOOR WHEN 
MOBILE  HOME IS NOT UNDERPINNED.  
Figure 13A 
(4) 3/8" x 1-1/2"  
(4) #10x1  
OUTSIDE AIR DUCT THROUGH 
UNDERPINNED.  
Page 26