Ceiling Exit (Using Close Clearance Listed Chimney) 
 
1.  Suspend a plumb bob from ceiling above unit so that weight is hanging in center of flue 
exit. (A small weight on a string will serve as a plumb bob).  Mark ceiling where string  is 
suspended  to locate center of  chimney hole. 
 
2.  After locating center of hole, install ceiling support box, chimney or chimney connector, 
flashing and rain cap using listed 2100° HT chimney only. Only use pipe listed in this 
manual. 
 
CAUTION  
 
REFER  TO CHIMNEY MANUFACTURERS INSTRUCTIONS  FOR ASSEMBLY AND 
DISASSEMBLY OF CHIMNEY PARTS.  BE SURE TO FOLLOW CHIMNEY INSTRUC-
TIONS FOR PROPER CLEARANCES TO COMBUSTIBLE AND PROPER AIR SPACING 
REQUIRED
.             
 
  3.  Add additional pipe until both of the following are met: 
24" min.
(610 mm)
 
OUTSIDE AIR DUCT THROUGH FLOOR WHEN 
MOBLE HOME IS NOT UNDERPENNED
RAIN CAP
FLASHING
RADIATION SHIELD
24" min.
(610 mm)
 
OUTSIDE AIR DUCT THROUGH UNDERPENNED
RAIN CAP
FLASHING
RADIATION SHIELD
36" TYP.
36" TYP.
20 FT. MAX.
Figure  12 
 
OUTSIDE AIR DUCT THROUGH UNDERPINNING
 
OUTSIDE AIR DUCT THROUGH FLOOR 
WHEN MOBILE IS NOT UNDERPINNED
 
Page 27