POSSIBLE TOOLS NEEDED FOR INSTALLATION 
 
If you decide to install your own stove, there are several hand tools you may need to do the job. 
If you do not already have them, they are readily available at most hardware stores. 
 
Caulking gun 
Large adjustable wrench (may not be needed) 
Drop cloths or newspapers 
Vacuum cleaner or whisk broom 
Flashlight 
1 tube of RTV silicone, Code 103 or 106, or high temperature rubber cement rated between 
450
o
 F- 600
7/32" drill bit and drill 
Socket/Ratchet Set 
 
INSTALLATION PREPARATION 
 
Fireplace: 
 
1.  Locate furniture and other materials away from front of fireplace to allow free access to  
fireplace. 
2.  Cover hearth and adjacent floor areas with a drop cloths to protect from soiling or marring 
surface. 
3.  Remove existing fireplace damper plate. 
4. Thoroughly clean fireplace of ashes and soot. 
5.  Check chimney and smoke chamber for excessive buildup of creosote or soot.  Also, check 
for obstructions, such as bird’s nests.  If chimney is excessively dirty, clean it or have 
someone clean it professionally BEFORE installing or using room heater. 
6. 
If fireplace has an ash dump or outside air provision, these must be sealed off with metal or 
tightly packed non-combustible insulation to prevent cold air from entering fireplace 
chamber.
 
MASONRY INSERT INSTALLATION 
INSTALLATION OPTIONS
 
This unit (appliance) may be installed into an all masonry fireplace, built in accordance with  
Uniform Building Code and National Fire Protection Association (NFPA 211). 
NOTE: Check with local building officials for any permits required for installation of this unit 
and notify your insurance company before proceeding with installation
 
 
In cases such as improperly drawing fireplaces, oversize flue liners or to meet codes in certain 
areas it is recommended that one of the flowing procedures be followed: 
      A. A Chimney Connector be installed from appliance flue exit through damper, plus     
           a air-tight face seal. See option (A)  page 8. 
      B. A listed Direct Connect be installed from appliance flue exit through damper,  
           into first section of flue liner with air-tight seal. See option (B)  page 8. 
      C. A Positive Connect be installed from appliance flue exit continuing up through  
           entire chimney and exiting at top of chimney.  See option (C)  page 8. 
Page 7