NEC 2400 PX ユーザーズマニュアル

ページ / 1089
NEAX2400 IPX Feature Programming Manual
NDA-24297, Issue 1
Page 297
Delay Announcement - UCD
D-31
Service Conditions (cont’d)
The figure below illustrates the three possible Delayed Announcement recording patterns.
10.
This feature can be programmed in Local Data Memory (LDM).
11.
Delay Announcement Trunk (DAT) in the node accommodating the UCD controlling station must be used
for this feature for the FCCS network.
Interactions
1.
UNIFORM CALL DISTRIBUTION [U-3] must first be provided.
2.
When a UCD station is assigned as the destination of LDN Night Connection, this service cannot be
activated.
Programming
STEP 1:
ASYD
- System Data 1, Index 70, Bit 6. Are DELAY ANNOUNCEMENT-UCD common or separate
for all UCD groups? 0/1: Common/Separate.
STEP 2:
ARTD
- Assign the Announcement Route as follows:
BOTHWAY TIE LINES:
RT: 1
1-OSGS
:2
2-ONSG
:3
3-ISGS
:2
4-INSG
:3
5-TF
:3
6-TCL
:4
7-L/T
:1
8-RLP
:2
15-LSG
:5
STEP 3:
ATRK
- Assign the LENs, Announcement Route Number, Trunk Number, and Tenant Number.
STEP 4:
MBTK
- Assign the Make Idle status to the announcement trunks.
STEP 5:
AUAD/AUADL
- This command is used to assign the DELAY ANNOUNCEMENT-UCD.
Assign the following information:
TN/UGN:
Tenant Number of UCD Control Station
STN/TELN: Station Number of UCD Control Station
DLYT:
Delay Timer (0-30 sec; 2 second, even-number increments)
MSGT:
Message Timer (0-30 sec; 2 second, even-number increments)
RP:
Announcement Output Reply
0:
Only One
1:
Replay
INT:
Replay Interval
 
                            
0 sec.
8
18
24
32 sec.
PATTERN I
6
ANNOUNCEMENT
12
6
6
24
IDLE TIME
PATTERN II
PATTERN III
18
ANNOUNCEMENT
IDLE TIME
ANNOUNCEMENT
IDLE TIME