National Instruments NI-488.2 ユーザーズマニュアル

ページ / 135
Chapter 3
Developing Your NI-488.2 Application
© National Instruments Corporation
3-17
Running Existing NI-488.2 Applications
Running Existing Win32 and Win16 NI-488.2 Applications
The NI-488.2 software includes the necessary components to allow 
existing Win32 and Win16 NI-488.2 applications to run properly.
Running Existing DOS NI-488.2 Applications Under Windows 98/95
To configure the NI-488.2 software to run existing DOS NI-488.2 
applications, complete the following steps:
1.
Make sure that no older version of the NI-488.2 DOS device driver is 
being loaded from your 
config.sys
 file. To do so, complete the 
following steps:
a.
Locate your 
config.sys
 file and open it for editing.
b.
Find the following line:
device=<path>\gpib.com
where 
<path>
 refers to the drive and directory where 
gpib.com
 
is located.
c.
If that line appears, type 
REM
 at the beginning of the line, as 
follows:
REM device=<path>\gpib.com
d.
Save your 
config.sys
 file and close it.
2.
Select Start»Programs»National Instruments NI-488.2»Explore 
GPIB
 to start Measurement & Automation Explorer.
3.
Expand the Devices and Interfaces directory by clicking on the + next 
to the folder.
4.
Select your GPIB interface and select Tools»Settings»NI-488.2 from 
the Explorer menu.
5.
Enable or disable DOS support in the NI-488.2 Settings dialog box 
and click on the OK button.
6.
If you are prompted to do so, restart your system.