National Instruments NI-488.2 ユーザーズマニュアル

ページ / 135
Chapter 3
Developing Your NI-488.2 Application
3-18
www.natinst.com
Running Existing DOS NI-488.2 Applications under Windows 2000/NT
To run DOS NI-488.2 applications, you must enable NI-488.2 DOS 
support under Windows 2000/NT. To enable NI-488.2 DOS support in 
Windows 2000/NT, complete the following steps:
1.
Open your 
config.nt
 file, located in the Windows 2000/NT 
system32 directory (for example, 
c:\windows\system32
).
2.
Find the following lines:
REM ***To run DOS GPIB applications, uncomment the
REM ***following line
REM device=<path>\doswin16\gpib-nt.com
where 
<path>
 is the directory in which you installed the NI-488.2 
software.
3.
Remove 
REM
 from the last line so that it reads as follows:
device=<path>\doswin16\gpib-nt.com
To disable DOS support, add 
REM
 back to the line where it was removed.