Multiquip Appliance Trim Kit MVH406DSCPAS ユーザーズマニュアル

ページ / 104
mvh406dsz/dsCpas pLaTe COmpaCTOR • OpeRaTiOn and paRTs manuaL — Rev. #7 (02/28/14) — page 17
5.  When adding hydraulic oil, only fill to the specified oil 
level as marked on the front of the hydraulic oil tank 
(Figure 7).
 dO nOT overfill.
Figure 7. Oil Tank (Front View)
Checking the air Cleaner
1.  To check the engine oil level, place the compactor on 
secure level ground with the engine stopped.
2.  Loosen the wing nut (Figure 8), remove the air cleaner 
cover.
Figure 8. Checking the Air Cleaner
  CauTiOn
dO nOT overfill hydraulic oil tank. This could cause 
oil leaks and sluggish operation. Clean cap and 
surrounding area before opening to prevent  dirt from 
entering oil tank.
OIL LEVEL
OIL
TANK
WING
NUT
AIR
CLEANER
INSpECTION
3.  Remove the air cleaner element (Figure 9) and inspect 
it for signs of wear or dirt. If air cleaner element is dirty, 
clean or replace element.
Figure 9. Air Cleaner Element
Checking The Fuel
1.  Remove the fuel cap located on top of fuel tank.
2.  Visually inspect to see if fuel level is low.  If fuel is  low, 
replenish with diesel fuel (Figure 10 ).
3.  When refueling, be sure to use a strainer for filtration. 
dO nOT top-off fuel. Wipe up any spilled fuel.
Figure 10. Refueling
ELEMENT
  dangeR
eXpLOsive FueL!
Motor fuels are highly flammable and can 
be dangerous if mishandled. 
dO  nOT 
smoke while refueling. 
dO nOT attempt 
to refuel  if the engine is hot or running.