Leica TPS - System 1000 1000Z01 ユーザーズマニュアル

ページ / 347
136
TPS-System 1000 Programs-2.3.1en
© Leica
IV
EL
AH
OH
BS
SM
AS
FS
BL
HB
KM
FB
SA
Results of sets of angles are recorded in the activ file
for measurements. (For details see dialog "FORMATS
AND MORE INFORMATION" )
Show the results of individual measurements on the
screen. ( For details see dialog "MORE INFORMATI-
ON"
)
Exit the program
• Formats and Data Recording
The following format is used to record results in the
activ file for measurements.
Number of measurements and accuracies.
WI 41
Code "HZ-RESLT" or "V0-RESLT"
WI 42
Number of targets.
WI 43
Number of observed sets.
WI 44
Standard deviation of a horizontal or
vertical direction.
WI 45
Standard deviation of a horizontal or a
vertical direction averaged from all sets.
HZ-RESLT: (Number of observations and accuracies)
Code
Number of
targets
Number of
sets
mR
mM
=4
=3
= 52"
= 37"
410039+HZ-RESLT 42....+00000004 43....+00000003 44....+00000520 45....+00000370
WI 41
WI 42
WI 43
WI 44
WI 45