HP AUTOMATIC XT SPAY GUNS 311051D ユーザーズマニュアル

ページ / 38
Installation 
10
311051D
Installation
The Automatic XT spray guns were designed to produce 
the highest quality finish with today's fluids as well as 
the low V.O.C. (volatile organic compound) fluids of 
tomorrow. 
This spray gun can spray most coatings or finishes cur-
rently being used for automotive, industrial, aerospace, 
marine, wood, plastic and architectural applications, 
while easily operating from paint delivery systems, such 
as pressure pots or remote pumps for production line 
operation.
The air regulator must have a minimum air flow capacity 
of 30 scfm at 100 psi (0.7 MPa, 7 bar) air pressure. 
Ventilate Spray Booth
Configure Gun and Manifold
The gun is supplied with an internal fluid plug and seals 
(19, 20, 21). To use the gun in a circulating system, 
remove the internal plug. In a non-circulating system, 
leave the plug in place to minimize flush time.
Circulating System 
1.
Apply anti-seize lubricant to the threads and mating 
faces of the manifold (101) and the elbows (107), 
supplied unassembled.
2.
Install the elbows (107) in both fluid ports of the 
manifold (101).
3.
Connect the fluid supply line to one elbow and the 
fluid return line to the other. The manifold fluid ports 
are reversible.
4.
Install the gun on the manifold, using the four 
screws (13). Start the threads of all four screws. 
Tighten the front two screws first, and then tighten 
the back two. Torque all four screws evenly to 65 
in-lb (7.3 N•m).
Non-circulating System
1.
See F
. 3. See Apply anti-seize lubricant 222955 to 
the threads and mating faces of the manifold (101), 
plug (109), and elbow (107), supplied unassembled.
2.
Install an elbow (107) in one fluid port of the mani-
fold (101), and a plug (109) in the other port.
3.
Install the internal plug (5) in the gun fluid port on 
the same side as the manifold plug. 
4.
Connect the fluid supply line to the fluid inlet elbow 
(107).
5.
Install the gun on the manifold, using the four 
screws (13). Start the threads of all four screws. 
Tighten the front two screws first, and then tighten 
the back two. Torque all four screws evenly to 65 
in-lb (7.3 N•m).
Check and follow all National, State, and Local 
codes regarding air exhaust velocity requirements.
Check and follow all local safety and fire codes.
F
IG
. 3: Non-Circulating Setup Shown (cutaway view)
TI8587b
1
Remove when used in circulating systems.
1
Replace with elbow (107) when used in circulating systems.
2
2
19
101
107
109
21
20