HP AUTOMATIC XT SPAY GUNS 311051D ユーザーズマニュアル

ページ / 38
Installation
311051D
11
Install Air Fittings
1.
Install the supplied 1/4 in. tube fitting into the cylin-
der (CYL) air port.
2.
Install 3/8 in. tube fittings into the atomization 
(ATOM) air port and the fan (FAN) air port.
Ground System
The following grounding instructions are minimum 
requirements for a system. Your system may include 
other equipment or objects that must be grounded. 
Check your local electrical code for detailed grounding 
instructions for your area and type of equipment. Your 
system must be connected to a true earth ground. 
Ground Pump/Fluid Supply
Ground the pump by connecting a ground wire and 
clamp between the fluid supply and a true earth ground 
as instructed in your separate pump instruction manual.
Ground Air Compressors and Hydraulic 
Power Supplies
Ground the air compressors and hydraulic power sup-
plies according to the manufacturer recommendations.
Ground Spray Gun
Ground the spray gun by mounting the manifold to a 
properly grounded reciprocator, robot, or stationary 
mount. Check the electrical resistance between the 
manifold and a true earth ground. The resistance must 
be less than 1 megohm.
Ground Fluid Supply Container
Ground the fluid supply container according to local 
code.
Ground Object Being Sprayed
Ground the object that is being sprayed according to 
local code.
Ground Solvent Pails
Ground all solvent pails that are used when flushing 
according to local code. Use only metal pails, which are 
conductive. Do not place the pail on a non-conductive 
surface, such as paper or cardboard, which interrupts 
the grounding continuity.
F
IG
. 4: Air Fittings
CYL
ATOM
FAN
TI8211a