HP AUTOMATIC XT SPAY GUNS 311051D ユーザーズマニュアル

ページ / 38
Setup 
14
311051D
Flush Spray Gun
Before running any paint through the spray gun: 
1.
Flush the gun with a solvent that is compatible with 
the fluid to be sprayed, using the lowest possible 
fluid pressure and a grounded metal container.
2.
Position Air Cap
Air caps are factory-set with the alignment pin (A) set to 
a vertical spray pattern. To change the air cap to a hori-
zontal spray pattern, use a needle nos pliers to unscrew 
the alignment pin (A) and relocate it to the horizontal 
spray pattern hole. When relocating the pin use low 
strength thread locker. Torque to 1.5-2.5 in-lb (0.2-0.3 
N•m). Do not overtighten. Refer to F
IG
. 11.
F
IG
. 10: Manifold Ports
Side Mounted Manifold Ports
Bottom Mounted Manifold Ports
FAN
ATOM
CYL
FAN
ATOM
CYL
KEY
N Cylinder Air Inlet: accepts 1/4 in. (6.3 mm) O.D. tubing
P Atomization Air Inlet: 3/8 in, (9.5 mm) O.D. tubing
R Fan Air Inlet: 3/8 in. (9.5 mm) O.D, tubing
S Fluid Inlet: 1/4 npsm
T Fluid Outlet (circulating gun only): 1/4 npsm
N
S (or T)
T (or S)
R
P
N
S (or T)
T (or S)
R
P
TI8096a
TI8097a
F
IG
. 11: Position Air Cap
Vertical Pattern
Horizontal Pattern
TI8171a
TI8170a
A
TI8172a