HP AUTOMATIC XT SPAY GUNS 311051D ユーザーズマニュアル

ページ / 38
Setup
311051D
15
Adjust Spray Pattern
The spray gun fluid flow is controlled by the fluid pres-
sure regulator and the fluid control knob. Use the fluid 
pressure regulator to adjust the general fluid flow and 
the fluid control knob to make precise fluid flow adjust-
ments.
Follow these steps to establish the correct fluid flow and 
air flow:
1.
To achieve desired flow, adjust the fluid flow using 
the fluid pressure regulator (L) installed in the gun 
fluid line. Typical industrial flow rates will vary with 
regulator pressures from 5 to 30 psi (34 to 210 kPa, 
0.3 to 2.1 bar). If the fluid pressure is too low at the 
desired flow rate, install a smaller nozzle. If the fluid 
pressure is too high, install a larger nozzle.
For spray guns equipped with the fluid control knob, 
you can make flow rate changes at the spray gun. 
Rotate the fluid control knob clockwise to reduce the 
flow.
2.
Using the air pressure regulator (F), set the fan and 
atomizing air supply pressure per Table 1. Use 
these suggested settings as a starting point. 
Table 1: Suggested Starting Settings
Do not exceed 100 psi (0.7 MPa, 7 bar) maximum fluid 
and air pressure. Higher pressures can cause parts to 
rupture and result in serious injury.
CAUTION
Use caution when operating the fluid control valve 
near the closed position. The plastic needle tip may 
be damaged if forced too hard against the nozzle seat 
by the fluid control valve.
F
IG
. 12: Fluid Pressure Regulator
L
TI7019a
A larger fluid nozzle at a reduced fluid pressure will 
maintain the same flow rate, but the fluid stream 
(velocity) will slow down. When air is applied, this 
allows air to act on the fluid longer and improve the 
atomization.
Fan Air (psi)
Atomization Air 
(psi)
Airspray
35
35
HVLP
25
25
Compliant
18
25
HVLP and Compliant Gun Limits
HVLP Guns: local laws may limit the maximum 
pressure to 10 psi (70 kPa, 0.7 bar) at the air cap 
for compliance. 35 psi (25 kPa, 2.5 bar) inlet air 
yields 10 psi (70 kPa, 0.7 bar) at the air cap. To 
measure pressure at the air cap, use the accessory 
tapped air cap. SeAccessories, page 33.
Compliant Guns: the maximum inlet pressure to the 
manifold is 30 psi atomizing air.