Troubleshooting 
20
311051D
Troubleshooting
General Troubleshooting
Check all possible remedies in the troubleshooting 
charts before disassembling the gun.
Some improper patterns are caused by the 
improper balance between air and fluid. Refer to 
Spray Pattern Troubleshooting, page 22.
Problem
Cause
Solution
Fluid leakage through venting holes.
Worn packing (17) or needle (5).
Replace packing or needle.
Air leakage through venting hole.
Worn o-ring (9) or gasket (15).
Check and replace parts as needed.
Air leakage from back of gun.
Worn o-rings (8, 9).
Replace o-rings.
Air does not trigger.
Piston stem is disconnected from 
main body of piston assembly (3).
Cylinder air pressure is too low.
Replace piston assembly.
Increase cylinder air pressure to 50 
psi.
Air does not shut off. 
Piston assembly not seating properly.
Broken return spring (7).
Swollen o-ring (8).
Worn piston stem o-rings (10, 11).
Bottom gasket (12) failed.
Clean/service piston assembly. 
Replace worn or swollen o-rings.
Replace return spring.
Replace o-rings.
Replace o-rings.
Replace gasket.
Fluid leakage from front of gun.
Fluid needle tip (5a) is dirty, worn, or 
damaged. 
Dirty or worn nozzle (23).
Clean or replace fluid needle tip or 
entire needle (5).
Clean or replace nozzle.
Fluid is present at air cap holes.
Nozzle (23) is insufficiently tightened 
or sealing o-ring (36) is damaged.
Tighten or replace o-ring.