Troubleshooting 
22
311051D
Spray Pattern Troubleshooting
Problem
Cause
Solution
Fluid flow is fluttering while spraying. Fluid nozzle is not tight enough.
O-ring (36) is missing or damaged.
Fluid filter is clogged.
Tighten fluid nozzle to 60 in-lb (6.8 
N•m).
Replace o-ring.
Check fluid filter.
Fluid flow fades while spraying high 
viscosity fluids.
Fluid pressure is too low, causing 
fluid flow to reduce when gun is ele-
vated.
Raise fluid pressure at source or use 
a smaller fluid nozzle.
Pattern becomes off-set of heavy on 
ends.
Air cap horn holes plugged or dam-
aged.
Clean air cap horn holes with 
non-metallic item such as a toothpick, 
or replace air cap.
Gun fluid pressure is too high with 
gun triggered.
Using needle/nozzle kit with too small 
orifice.
Use needle/nozzle kit with larger ori-
fice.
Fluid system will not operate at low 
enough fluid pressure [below 10 psi 
(70 kPa, 0.7 bar)].
There is no fluid regulator, or air reg-
ulator on pressure pot is not sensitive 
enough at low pressures.
Add low pressure fluid regulator, or 
add more sensitive low pressure air 
regulator on pressure pot.