HP AUTOMATIC XT SPAY GUNS 311051D ユーザーズマニュアル

ページ / 38
Service
311051D
23
Service
Items Needed for Service
1/16 in. Hex Wrench - provided
3  mm  Hex  Wrench
Adjustable Wrench
4  mm  Hex  Wrench
Pliers
Lubricant part no. 111265; seAccessories, page 
33, to order
Compatible Solvent
Replace Fluid Packings and Air 
Seals
1.
2.
Unscrew the four screws (13) and remove the gun 
from the manifold.
3.
Remove the air cap retainer (25) and air cap (24). 
See F
4.
Remove the piston cap (4) from the piston housing 
(1). Remove the springs (6, 7).
5.
Using a 1/16 in. hex wrench loosen the fluid needle 
set screw (30). Remove the needle stop (29).
6.
Pull the fluid needle (5) out the back of the gun.
7.
Check the fluid needle (5) for damage or excessive 
wear. Replace the needle tip (5a) or the entire nee-
dle if necessary. 
8.
Remove nozzle (23). Check nozzle and o-ring (36) 
for damage. You may need to use a pick to remove 
o-ring from housing (2).
9.
Remove the piston. Using a pliers, pull the piston (3) 
out of the piston housing (1). See F
10. Unscrew the two screws (14) and separate the fluid 
housing (2) and the piston housing (1). Remove 
gasket (12) only if it needs to be replaced. See F
11. Remove the packing nut (16) with a wrench.
12. Remove the fluid packing (17) from the nut (16). 
Discard the old fluid packing.
Air Section Repair Kit 288171 and Fluid Section 
Repair Kit 288135 are available. Purchase the kits 
separately.
F
IG
. 18
TI8102a
24, 25
23
13
4
F
IG
. 19
F
IG
. 20
36
TI8198a
14
14
1
2
TI8173a