Honeywell Galaxy 3-48C インストール手順
Galaxy 3 Series Installation Manual
5-4
Configuring as a Stand-Alone MAX
3
1. Ensure that the MAX
3
is connected to the Galaxy (RS485 AB line) and the MAX mode is enabled
(option 63.2.1 = OPTIONS.MAX.MAX Mode).
2. Select option 63.2.2 = OPTIONS.MAX.MAX Address and press the ent key; the Galaxy
searches for the MAX
3
with the highest address (the new MAX
3
reader). The Galaxy panel may prompt
(depending on model) for the AB line (1 – 4) that is to be searched; select the line and press the ent key.
On locating the MAX address, the keypad prompts for the
On locating the MAX address, the keypad prompts for the
OPERATING MODE
of MAX to be assigned:
select 1 = Standalone and press the ent key. The MAX
3
reader is readdressed as 32.
When the reprogramming is complete the MAX
3
bleeps, LED 3-7 on the MAX
3
switches on and the keypad
display returns to 2 = MAX Address.
3. Disconnect the AB line from the MAX
3. Disconnect the AB line from the MAX
3
reader. Ensure that all other modules (keypads, RIOs and on-line
MAX
3
readers) are still daisy-chained into the Galaxy panel. If the MAX
3
reader is the last module on the
AB line, remove the 680
Ω end of line resistor and put it into the last module on the line.
4. The MAX
3
reader is now programmed as a stand-alone module in sleep mode (LEDs 3–7 on) and can
be programmed using the MAX
3
cards (refer to Programming Stand-Alone MAX
3
Readers).
Figure 5-3. MAX
3
LED’s
Configuring MAX
3
(cont’d)
x
P
MAX
3
1 = Read (Amber)
2 = Open (Green)
3 = Closed (Red)
4 = Nightlock (Red)
5 = Add (Red)
6 = Void (Red)
7 = Program (Red)