GE General Electric Sewing Machine AF-300 ユーザーズマニュアル
-63-
(3) Undervoltage(LU) (4)Overheating of heat sink (OH1)
(5) External alarm input (OH2)
Has (momentary) power fail-
ure occurred?
ure occurred?
Reset and restart o pera-
tion. (If F14 is 0,1)
tion. (If F14 is 0,1)
Faulty parts or loose connec-
tion in power control circuit?
tion in power control circuit?
Replace faulty parts and
fix connection.
fix connection.
Power supply voltage within
specified value?
specified value?
Any load requiring large
starting current within the
same power distribution
group?
starting current within the
same power distribution
group?
Modify power distribu-
tion system to satisfy
specified value.
tion system to satisfy
specified value.
Does LU activate when cir-
cuit breaker or magnetic con-
tractor switched to ON?
cuit breaker or magnetic con-
tractor switched to ON?
Probable faulty control circuit
of drive or error because of
noise, etc. Contact GE Fuji
of drive or error because of
noise, etc. Contact GE Fuji
Power transformer ca-
pacity adequate?
pacity adequate?
Probable faulty drive.
Contact GE Fuji
Contact GE Fuji
LU
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Yes
Heat sink overheat-
ing (OH1)
ing (OH1)
Load excessive?
Reduce load.
Probable faulty drive
or error because of
noise, etc. Contact
or error because of
noise, etc. Contact
GE
Fuji
.
Ambient temperature
within specified value?
within specified value?
Cooling air passage
blocked up?
blocked up?
Cooling fan rotating?
Arrange peripheral
conditions to secure
specified value.
conditions to secure
specified value.
Remove obstacles.
Replace cooling fan.
Yes
Yes
No
No
No
Yes
Yes
No
OH2
Connect alarm signal con-
tact. Short-circuit between
terminals THR - CM if no
signal is input.
tact. Short-circuit between
terminals THR - CM if no
signal is input.
Signal from external de-
vice connected between
control circuit terminals
THR - CM?
vice connected between
control circuit terminals
THR - CM?
Is the alarm function of
the external device operat-
ing correctly?
the external device operat-
ing correctly?
Probable faulty drive or
error because of noise.
Contact GE Fuji.
error because of noise.
Contact GE Fuji.
Remove the cause of alarm
function activation.
function activation.
Yes
No
No
Yes