GE General Electric Sewing Machine AF-300 ユーザーズマニュアル

ページ / 98
 
-63- 
 
(3) Undervoltage(LU)                           (4)Overheating of heat sink (OH1) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
(5) External alarm input (OH2)                 
Has (momentary) power fail-
ure occurred?
 
Reset and restart o pera-
tion. (If F14 is 0,1) 
Faulty parts or loose connec-
tion in power control circuit? 
 
Replace faulty parts and 
fix connection. 
Power supply voltage within 
specified value?
 
Any load requiring large 
starting current within the 
same power distribution 
group?
 
Modify power distribu-
tion system to satisfy 
specified value. 
Does LU activate when cir-
cuit breaker or magnetic con-
tractor switched to ON?
 
Probable faulty control circuit 
of drive or error because of 
noise, etc. Contact GE Fuji
 
Power transformer ca-
pacity adequate?
 
Probable faulty drive. 
Contact GE Fuji 
 
LU 
No
 
No
 
No
 
No
 
No
 
Yes
 
Yes
 
Yes
 
Yes
 
Yes
 
Yes
 
Heat sink overheat-
ing (OH1)
 
Load excessive? 
Reduce load. 
Probable faulty drive 
or error because of 
noise, etc. Contact 
GE 
Fuji
Ambient temperature 
within specified value? 
Cooling air passage 
blocked up? 
Cooling fan rotating?
 
Arrange peripheral 
conditions to secure 
specified value. 
Remove obstacles. 
Replace cooling fan. 
Yes
 
Yes
 
No
 
No
 
No
 
Yes
 
Yes
 
No
 
OH2 
Connect alarm signal con-
tact.  Short-circuit between 
terminals THR - CM if no 
signal is input. 
Signal from external de-
vice connected between 
control circuit terminals 
THR - CM? 
Is the alarm function of 
the external device operat-
ing correctly? 
Probable faulty drive or 
error because of noise.  
Contact GE Fuji. 
Remove the cause of alarm 
function activation. 
Yes
 
No
 
No
 
Yes