GE General Electric Sewing Machine AF-300 ユーザーズマニュアル

ページ / 98
 
-65- 
(7) Memory error (Er1)  CPU error (Er3) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
(8) RS485 Communication Error (Er8) [In case RS485 communication is not used] 
 
 
 
 
 
 
 
 
 
   * For Er8 measures when using RS485, refer to the instruction manual for optional RS485  
communication card. 
Set o00 to 0. 
o00 is set to 1? 
No
 
Yes
 
Probable faulty drive. 
Contact GE Fuji.
 
Communication  
Error  Er8 
No
 
Reset analog frequency to 
positive value. 
Analog frequency set to 
negative value? 
Remedy faulty parts.
 
Memory error  
 Er 1 
CPU error 
 Er 3 
Yes
 
Turn power OFF then ON 
again after CHARGE lamp 
has gone out.
 
Noise source nearby?
 
Is data displayed on LED?
 
Probable faulty drive.  
Contact GE Fuji.
 
Drive is normal.  Continue 
operation.
 
Yes
 
No
 
Yes
 
No
 
Abnormal dis-
play or indica-
tion goes out