Minor Error Codes
The meaning of each Minor Error Code depends upon the Major Error Code for which it is
defined.  Consult the appropriate Minor Error Code table for the indicated Major Error Code.
Minor Error Codes for Major Error Codes 05H (at  Remote Server PLC) and
85H (at Client PLC)
Error Status
Service Request Error Description
(Hexadecimal)
C105H/C185H
Invalid block state transition.
C305H/C385H
Text length does not match traffic type.
C605H/C685H
Control Program (CP) tasks exist but requestor not logged into main CP.
C705H/C785H
Passwords are set to inactive and cannot be enabled or disabled.
C805H/C885H
Password(s) already enabled and cannot be forced inactive.
C905H/C985H
Login using non-zero buffer size required for block commands.
CA05H/CA85H Device is write-protected.
CB05H/CB85H
A comm or write verify error occurred during save or restore.
CC05H/CC85H
Data stored on device has been corrupted and is no longer reliable.
CD05H/CD85H Attempt was made to read a device but no data has been stored on it.
CE05H/CE85H
Specified device has insufficient memory to handle request.
CF05H/CF85H
Specified device is not available in the system (not present).
D105H/D185H
Packet size or total program size does not match input.
D205H/D285H
Invalid write mode parameter.
D505H/D585H
Invalid block name specified in datagram.
D605H/D685H
Total datagram connection memory exceeded.
D705H/D785H
Invalid datagram type specified.
D805H/D885H
Point length not allowed.
D905H/D985H
Transfer type invalid for this Memory Type selector.
DA05H/DA85H Null pointer to data in Memory Type selector.
DB05H/DB85H Invalid Memory Type selector in datagram.
DC05H/DC85H Unable to find connection address.
DD05H/DD85H Unable to locate given datagram connection ID.
DE05H/DE85H
Size of datagram connection invalid.
DF05H/DF85H
Invalid datagram connection address.
E005H/E085H
Service in process cannot login.
E405H/E485H
Memory Type for this selector does not exist.
E905H/E985H
Memory Type selector not valid in context.
EA05H/EA85H
Not logged in to process service request.
EE05H/EE85H
Could not return block sizes.
EF05H/EF85H
Programmer is already attached.
F005H/F085H
Request only valid in stop mode.
F105H/F185H
Request only valid from programmer.
F205H/F285H
Invalid program cannot log in.
F405H/F485H
Invalid input parameter in request.
F505H/F585H
Invalid password.
F605H/F685H
Invalid sweep state to set.