SOLUTION
•  DO NOT light the burner.  Extinguish any 
open flame near the spill.  Wipe up the spill, 
and wait several minutes for the residue to 
evaporate.  If you see no additional fuel on 
the ground, you may light the burner.  If you 
see additional fuel on the ground, you might 
have a leak.  DO NOT use this appliance if it 
leaks fuel.
•  The appliance may not be level.  Check 
to make sure the appliance is level, and 
shim under the grate legs or rear support, if 
necessary.  Shim only with metal washers or 
other non-flammable objects.
•  A small piece of foil that covers the opening 
of the illuma-fuel™ canister might be 
obstructing the piercer tube.  Open the fuel 
canister door on the front log.  Gently wiggle 
the fuel canister left to right and front to 
rear on the fuel canister tray to enlarge the 
opening in the foil.  DO NOT lift the illuma-
fuel canister from the tray, as this could 
cause a fuel spill.
•  The tubes connecting the burner to the fuel 
reservoir might be clogged.  Starting at the 
tube opening in the bottom of the burner, run 
a thin, flexible wire through the length of the 
tube to remove the obstruction.
•  The battery in the igniter may be dead.  
Replace them with new batteries.
•  The sparker tip may be out of position.  The 
tip of the sparker should be about ¼” above 
the level of the sparking point.  Carefully 
bend the wire so that the tip of the sparker 
wire is in this position
•  The fuel is cold or the appliance is cold.  
Use a long match or a long butane lighter to 
ignite the fuel.
PROBLEM
1. You see fuel on the ground near the 
appliance.
2. You do not see fuel in the burner prior to 
lighting the appliance and after installing a 
canister.
3. You push the igniter button but the appliance 
does not light.
XIII. TROUBLESHOOTING