Installation continued 
 
5.  Insert top screw into the wall, allowing it to protrude by approximately 3mm. 
6.  Hook wall box on to screw using keyhole slot provided. 
7.  Mark position of remaining fixings, remove box and complete fixing. 
8.  Fix the wall box to the wall, ensuring the drain hole is at the bottom. 
9.  Cable entries are made to the base of the box, using the holes provided. 
10.  Connect circuit wiring to terminal block. (see Fig.2.) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
11.  Plug detector head into the back box socket.  
      Secure detector to wall box with screws provided and cover screws with screw caps. 
 
Adjusting PIR Range 
 
 
 
 
 
 
 
 
 
 
Limit the range and angle of detection as appropriate by adjusting the detector head and by using the lens masking plates 
provided. Cut the appropriate segments from the lens mask to cover the area of the lens that requires masking. 
 
A1 
A2 
A3 
A4 
Long Range 6-15 metres 
B1 B2 B3  B4 
Inner 
Range 3-12 metres 
C1 
C2 
C3 
C4 
Short Range 0-3 metres 
     90º             45º               0                45º               90º 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
  
               
 
 
Masked Areas 
Masked Areas 
AC A4 
A1 A2 A4 
B3 B4 
B1 B2 B4 
C3 C4 
 
C1 C2  C4 
 N          N         
 
      SLI         L
N = Neutral to load 
 
N = Supply Neutral 
 
 
 
= Earth terminal 
 
SLI = Supply to load 
 
 
L = Supply live 
 
15m 12m 
3m 
3m 
12m
15m
C1 
C2  C3 
C4 
B4 
B1 
A4 
A1 
B2 
A2 
A3 
B3 
45º 
45º 
 
90º 
15m 
15m 
45º 
90º