Testing 
 
1.  Set the light level 
5
 to maximum (clockwise), and the time on   
 
    to minimum (anti-clockwise).
 
2. 
Move in and out of detection pattern checking the PIR detector switches load on and then off. Once the detection area has been set 
satisfactorily, adjust the time (blue knob) to the desired level. For your convenience optimum settings have been indicated. 
3. 
If the unit does not operate, refer to the check list and fault finding list. 
 
Check List  
 
1. 
Check the supply to the detector 
2. 
If the unit is being tested during daylight , ensure that the photocell has been adjusted in accordance with point 1 in the ‘Testing’ 
section. 
3. 
Check detector is connected to the heater correctly 
 
Fault Finding List 
 
 
Problem Solution 
 
 
The unit will not switch on 
• 
Check power is supplied to the unit 
• 
Check the plug in connection from the detector head is inserted in to the wall box correctly 
• 
Check to see that the lamps are fitted correctly to the heater(s) 
Unit is detecting at too long a range 
• 
Check mounting height and adjust angle of the unit downwards to reduce range (note the unit is 
designed to switch at a maximum of 15 metres with 170Ib (77kg) person walking at 90º to the 
unit. Alternatively fit an appropriate mask. 
IMPORTANT: at 10ºC this unit may detect in excess of 20 metres. 
 
Unit switches on for no apparent 
reason 
• 
Check the unit is not sited near any vents or heating flues  
• 
Infra-red patterns are given off by electrical appliances 
NOTE: to reduce sensitivity, blank off areas C1, C2, C3, C4 of the lens mask 
 
Unit will not switch off 
• 
Are you standing by the detection zone? Whilst you are moving in and out of the detection area 
the unit will continue to detect. The heater on time is from the last moment detection was made.  
 
Technical Specification 
 
Switching capability – Up to 3kW 
Operating Power – 3kW 
Detection Range – 15 metres maximum 
Detection Angle - 180º 
Heater on time – Adjustable to 10 seconds, 60 seconds, 3.5 minutes, 6 minutes, 9 minutes, 12 minutes, 13.5 minutes,  
                            16 minutes, 21 minutes (approximately) 
 
IMPORTANT: When unit is first connected to the mains the light will switch on – even in daylight. 
                       Allow unit to reset before testing 
 
 
After Sales Care 
 
Your product is guaranteed for one year from the date of purchase. 
 
Within this period, we undertake to repair or exchange this product free of charge (subject to availability) provided it has been 
installed and operated in accordance with these instructions. 
 
Your rights under this guarantee are additional to your statutory rights, which in turn are not affected by this guarantee. 
 
Should you require after sales service you should contact the supplier through whom you purchased the product or contact our 
customer service help desk on 0845 600 5111. It would assist us if you can quote the model number, series, date of purchase, 
and nature of the fault at the time of your call. The customer service help desk will also be able to advise you should you need to 
purchase any spares. 
 
Please do not return a faulty product to us in the first instance as this may result in loss or damage and delay in providing you 
with a satisfactory service. 
 
Please retain your receipt as proof of purchase 
 
 
Glen Dimplex UK Ltd 
Millbrook House 
Grange Drive 
Hedge End 
Southampton 
SO30 2DF
 
 
UK customer helpline   (8.00AM-6.00PM Mon-Fri; 8.30AM-1.00PM Sat) 
 
Customer helpline         Tel.  0845 600 5111 
                                      Fax. 01489 773053 
                                      e-mail. customer.services@glendimplex.com 
 
Republic of Ireland        Tel.  01 842 4833 
[C] Glen Dimplex UK Ltd. 
All rights reserved. Material contained in this publication may not be reproduced in whole or part, without the prior permission in writing from 
Glen Dimplex UK Limited.