Whirlpool MEDB850YG インストール手順

ページ / 20
10
4.
 
Connect ground wire
F
A
Connect ground wire (green or bare) (F) of direct wire cable 
to external ground conductor screw (A). Tighten screw.
E
C
B
3.
 
Connect neutral ground wire  
      and neutral wire
Connect neutral ground wire (E) and place 
hooked end (hook facing right) of neutral 
wire (white or center wire) (C) of direct wire 
cable under center screw of terminal block 
(B). Squeeze hooked ends together and 
tighten screw.
2.
 
Prepare to connect neutral 
     ground wire and neutral wire
B
A
E
Remove center terminal block screw (B). Remove neutral 
ground wire (E) from external ground conductor screw (A).
Put direct wire cable through the strain relief. The strain 
relief should have a tight fit with the dryer cabinet and be in 
a horizontal position. Tighten strain relief screw against the 
direct wire cable.
2.
 
Attach direct wire cable  
     to strain relief 
3-wire direct connection:
Go to “3-Wire Direct Connection”  
on page 11.
4-wire direct connection:
Go to “4-Wire Direct Connection”  
on this page.
 
If your wiring looks like this:
4-wire Direct Wire Connection
 
IMPORTANT: 
A 4-wire connection is required for mobile 
homes and where local codes do not permit 3-wire connections. 
Direct wire cable must have 5 ft. (1.52 m) of extra length so 
dryer may be moved if needed.
Strip 5" (127 mm) of outer covering from end of cable,  
leaving bare ground wire at 5" (127 mm). Cut 1
1
/
2
" (38 mm)  
from remaining 3 wires. Strip insulation back 1" (25 mm).  
Shape ends of wires into hooks.
     1"
(25 mm)
       5"
(127 mm
)
1.
 
Prepare your 4-wire cable for  
     direct connection