VENTING REQUIREMENTS
VENTING
WARNING: 
To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling, attic, crawlspace, or a concealed space 
of a building. Only rigid or flexible metal vent shall be used for 
exhausting.
 
Only a 4" (102 mm) heavy metal exhaust vent and clamps  
may be used. 
 
Do not use plastic or metal foil vent.
Rigid metal vent:
 
Recommended for best drying performance and to avoid 
crushing and kinking.
Flexible metal vent: 
(Acceptable only if accessible to clean)
 
Must be fully extended and supported in final dryer location.
 
Remove excess to avoid sagging and kinking that may  
result in reduced airflow and poor performance.
 
Do not install in enclosed walls, ceilings, or floors.
 
The total length should not exceed 7
3
/
4
 ft. (2.4 m).
NOTE: 
If using an existing vent system, clean lint from  
entire length of the system and make sure exhaust hood  
is not plugged with lint. Replace plastic or metal foil vents  
with rigid metal or flexible metal vents. Review Vent System  
Chart and if necessary, modify existing vent system to  
achieve best drying performance.
4"
(102 mm)
4" (102 mm) heavy metal exhaust vent
C
B
E
Connect neutral ground wire 
and neutral wire
2. 
Connect neutral ground wire (E) and neutral wire (white or 
center wire) (C) of power supply cord or cable under center 
terminal block screw (B). Tighten screw.
Connect remaining wires
3.
Place hooked ends of remaining wires under outer terminal 
block screws (hooks facing right). Tighten screws. 
A
G
Connect external ground wire
4.
Connect a separate copper ground wire (G) from the external 
ground conductor screw (A) to an adequate ground. Finally, 
reinsert tab of terminal block cover into slot of dryer rear 
panel. Secure cover with hold-down screw. Now, go to 
“Venting Requirements.”