Installation Clearances
IMPORTANT: If installing a range hood or microwave hood 
combination above the range, follow the range hood or 
microwave hood combination installation instructions for 
dimensional clearances above the cooktop surface.
NOTES: 
After making the countertop cutout, some installations may 
require notching down the base cabinet side walls to clear the 
cooktop base. To avoid this modification, use a base cabinet with 
sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the 
countertop to the top of the drawer (or other obstruction) in base 
cabinet is required. The drawer depth may need to be shortened 
to avoid interfering with the regulator.
Electrical Requirements
IMPORTANT: The cooktop must be electrically grounded in 
accordance with local codes and ordinances, or in the absence 
of local codes, with the National Electrical Code, ANSI/NFPA 70 
or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate.
A copy of the above code standards can be obtained from:
 National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is 
required. A time-delay fuse or circuit breaker is also 
recommended. It is recommended that a separate circuit 
serving only this cooktop be provided.
Electronic ignition systems operate within wide voltage limits, 
but proper grounding and polarity are necessary. Check that 
the outlet provides 120-volt power and is correctly grounded. 
The Tech Sheet provided is located inside the cooktop on the 
left wall of the cooktop base.
A. 30
"
 (76.2 cm) on 30
"
 (76.2 cm) models; 36
"
 (91.4 cm) on 
36
"
 (91.4 cm) models
B. Combustible area above countertop (shown by dashed box above)
C. 30
"
 (76.2 cm) minimum clearance between top of cooktop platform 
and bottom of uncovered wood or metal cabinet (24
"
 [61.0 cm] 
minimum clearance if bottom of wood or metal cabinet is covered 
by not less than 
¹⁄₄
"
 [0.6 cm] flame retardant millboard covered with 
not less than No. 28 MSG sheet steel, 0.015
"
 [0.04 cm] stainless 
steel, or 0.024
"
 [0.06 cm] aluminum or 0.020
"
 [0.05 cm] copper). If 
installing a range hood see NOTES.*
D. 13
"
 (33.0 cm) recommended upper cabinet depth
E. 1
¹⁄₈
"
 (2.8 cm)
F. 20
"
 (50.8 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop 
within minimum horizontal clearances to cooktop
H. Grounded outlet - Locate within 24" (61.0 cm) of right rear corner of 
cutout
I. 29" (73.7 cm) on 30" (76.2 cm) models; 35¼" (89.5 cm) on 
36" (91.4 cm) models
J. 24" (61.0 cm) minimum countertop depth is required
K. 2
⁷⁄₈
" (7.3 cm) minimum distance to rear combustible surface
L. Gas line opening - Wall: anywhere 5" (12.7 cm) below underside of 
countertop. Cabinet floor: anywhere within 6" (15.2 cm) of rear wall 
is recommended
M. 8" (20.3 cm) minimum distance to nearest left side combustible 
surface.** 
N. 8" (20.3 cm) minimum distance to nearest right side combustible 
surface.**
30" (76.2 cm) Cooktop Overall: M + N must equal 48" (122.0 cm) 
minimum + 29" (73.7 cm) cutout for cooktop or 77" (195.6 cm)
36" (91.4 cm) Cooktop Overall: M + N must equal 48" (122.0 cm) 
minimum + 35¼" (89.5 cm) cutout for cooktop or 83¼" (211.5 cm)
**M + N combined must be at least 48" (122.0 cm) minimum overall
Example 1: M = 8" (20.3 cm) left side + N = 40" (101.6 cm) right side 
= 48" (122.0 cm)
Example 2: M = 24" (61.0 cm) left side + N = 24" (61.0 cm) right side 
= 48" (122.0 cm)
B
D
A
C
E
F
H
I
J
G
K
L
M
N
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING