Vogelzang International NORSEMANTM SOlid FuEl WARM AiR FuRNAcE 2500 ユーザーズマニュアル

ページ / 28
VGZ-018 / 0805.1 
NORSEMAN™ 1500/2500 FuRNAcE / 
Page 
locAtiNg FURNAcE continued…
Fig. 3 – Minimum plenum Clearances from Combustible Materials
CAUTION: kEEP FURNIShINgS 
AND  OThER  COmBUSTIBLE 
mATERIALS  AwAY  FROm ThE 
FURNACE.
tools & MAtERiAls REqUiRED FoR AssEMblY  
AND iNstAllAtioN
TOOLS REqUIRED
Safety Glasses
Gloves
Pencil
6 ft. Tape Measure
Tin Snips
Sabre Saw
Drill
1/8” dia. Drill Bit (for sheet metal screws)
Screwdrivers  (Phillips & slotted)
6mm Socket with Driver
10mm Socket with Driver
10mm open end box wrench
7/16” box wrench
mATERIALS REqUIRED
NotE: the following items are Not included with 
your furnace. 
chimney connection:  
6” black steel (24 ga. min.) straight furnace pipe, 
elbow, collar and Thimble (as required).
6˝ Barometric Draft Regulator (optional)
8˝ Round Butterfly Anti-Backdraft Damper
  (2 required – for parallel installation only)
Plenum & Duct Work (as required).
chimney:  Existing  6”  Lined  Masonry  chimney  
or 6” Inside Dia. Listed Type HT chimney.
1/2” Sheet Metal Screws
Electr ical  Wir ing:  18  ga.  AWG  copper  with  
90° c min.
1/2˝ conduit & connectors
Furnace cement (manufacturer recommends Rutland  
code 78 or equivalent)
N O T E :   B E F O R E   F I R I N g   
FURNACE, SLIDE FIREBRICkS 
TOwARDS REAR SO NO gAPS 
REmAIN BETwEEN BRICkS. DO 
NOT OPERATE FURNACE wITh 
CRACkED  OR  mISSINg  FIRE 
BRICkS.