Page 39 of 62 
8.9  FULL DISCHARGE. 
8.9.1.  Settings: 
8.9.1.1.  Set the Current selectors to zero.  
8.9.1.2.  Set the Time selectors to 1/01.  
8.9.1.3.  Set the Cell selector to 20. 
8.9.2.  Start the unit in the full discharge mode (red). Unit will run. Increase the 
discharge current selector to any value above 1 AMP (010). Unit will continue to 
run. 
8.9.3.  Switch to Auto discharge. Unit will go to Capacity Failure. Disconnect from the 
voltage source. Reset. 
 
8.10  CURRENT TRACKING. 
8.10.1.  Settings: 
8.10.1.1.  Set the Time selectors to 1/01 and the Cell selector consistent with the 
battery. 
8.10.1.2.  Set the main charge current selector to 25 AMPS (250) 
8.10.1.3.  Set the topping charge current selector to 1 AMP (010). 
8.10.2.  Connect the Battery Cable to the battery.  
8.10.3.  Start the unit in the two rate mode. Current will rise to 25.0A ±0.35A. 
8.10.4.  Switch to the single rate mode. Current will drop to 1.0A ±0.2A. Reset. 
8.10.5.  Repeat this test for other high and low settings. 
8.10.6.  Repeat also for the discharge mode. 
8.10.7.  NOTE: In discharge, the readings may be lower by 0.1A to 0.2A. 
8.10.8.  See 8.2.4 for adjustments 
 
8.11  VOLTAGE CONTROL. 
8.11.1.  See 8.2.7 for adjustments.