Precision Trading 60 R3.0 ユーザーズマニュアル

ページ / 62
Operator Manual, Supercharger 60 
R3.0 
 
Page 47 of 62 
•  NOTE 1: Other currents can also be used for High 
Current calibration (20A minimum).  
•  NOTE 2: Adjustments of R28 and R25 are 
interactive. Therefore, It will be necessary to repeat 
the adjustments once or twice to achieve exact 
results.   
•  The Voltage reading at E3 (shunt amplifier output) 
must correspond to the current as follows: voltage at 
E3 = -0.1V/A ±2%.  
•  Examples: 
40 A equals  -4.00V ±0.08V
 
20 A equals  -2.00V ±0.04V
 
10 A equals  -1.00V ±0.02V
 
5 A equals  -0.50V ±0.01V 
 
 
Figure 8 - Current Control Board Adjustments